Roof Anchor Testing Requirements

Roof anchor testing architectural building designs that incorporate large windows for lighting or aesthetic value will have the need for roof anchors.
Roof anchor testing requirements. Whether bolted embedded in concrete or welded roof anchors are the integral part of the fall arrest system used for window washing crews and other trades that would need to. In fact when testing systems under osha you are required to use a weight of 220 pounds plus or minus 3 pounds at a free fall of 6 feet 29 cfr 1926 subpart m appendix c. The system would fail. For example the new z359 18 standard requires a corrosion test for type t anchors whereby the anchorage connector is exposed to a salt spray for 500 hours.
Just a few of our roof anchor inspection services for example include but are not limited to the following. Where by the factory load testing of 2500lbs or half the. This of course means an extensive battery of tests as products are brought compliant with the new standard. Osha anchorage requirements for rds 1910 27 b 1 i now requires that before employers use a rope descent system the building owner must inform the employer in writing that the building owner has identified tested certified and maintained each anchorage so it is capable of supporting 5 000 pounds in any direction for each worker attached.
15 feet from all unprotected sides wac 296 155 24609 4 iii anchor load testing to ensure the anchor can support 5000 lbs per osha. Roof anchor point requirements are all about safety. Ghb fall protection believes that education is the first step to fall protection. Call today for information on implementing a safer workplace for tomorrow.
At applied technical services our comprehensive list of roof anchor services include design inspection installation and testing of roof anchors to help you create the safest possible working environment at all times. At least every 10 years roof anchors need to be proof tested to be capable of supporting a 5 000 lbs. They require all roof anchors to be lab tested to 2500 lbs half of its ultimate load. When it comes to fall protection testing and certification peak fall protection has the experience and expertise to perform osha and ansi mandated inspections to keep your fall protection system compliant.
This test is a design tool or as a comparison model. This is where we ll need to start for buildings that cannot provide this documentation. According to osha 1910 27 anchorages that support window washing rope descent systems should be tested and certified by a qualified person at intervals not to exceed 10 years. The previous z359 1 standard with which anchorages connectors are currently compliant has no such requirement.
In nsw there are a number of requirements that must be met to ensure anchor point safety particularly at heights.